Tweco Victor Thermal Dynamics Power Module Upgrade Kit Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
Manual 0-5326 13
33.Changethedatatagtoshownewupgradedpowerrequirementsandserialnumbersbylayingitoverthe
existing data tag just below the existing. The intent is to replace the power draw requirements while still
showing the machines original serial number.
Art # A-12360
From this to this
Reinstall the radiator
34.Carefullylifttheradiatorandsetonthebaseofthemachine.Noticetherearethreeslots.Onthebottomof
the radiator there are three tabs, set these tabs into the slots in the machine base. Reconnect the coolant lines.
Ensurethattheyarenotcrossedasthiswillaffectthecooling.
Art # A-12361
NOTE
Depending on which model of machine you are upgrading the installation of the radiator is different for
a 200A upgrade
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare