Tweco FP-38 Power Supply Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Tweco FP-38 Power Supply herunter. Tweco FP-38 Power Supply User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Power Supply

Plasma CuttingPower SupplyFirepower TM FP-38 Power SupplyOperating ManualMay 5, 2003 Manual No. 0-2967A-03286

Seite 2

GENERAL INFORMATION 1-6 May 14, 2002

Seite 3

Manual 0-2967 2-1 SPECIFICATIONSSECTION 2: SPECIFICATIONS15.75"400 mm10"254 mm21"0.53 m43 lb / 19.5 kgA-03378 6"150 mmA-033796&

Seite 4 - TABLE OF CONTENTS

SPECIFICATIONS 2-2 Manual 0-2967Electrical RequirementsInputPower Input Current InputVoltage Freq. (kVA)(Amps) Fuse (Amps) Wire (AWG) Wire (Canada)(Vo

Seite 5 - GENERAL INFORMATION

Manual 0-2967 3-1 INSTALLATIONSECTION 3: INSTALLATION3.1 Unpacking1. Use the packing lists to identify and account for each item.2. Inspect each item

Seite 6 - 1.03 Publications

INSTALLATION 3-2 Manual 0-29673.3 Primary Input Power Connections CAUTIONCheck your power source for correct voltage before plugging in or connecting

Seite 7

Manual 0-2967 3-3 INSTALLATION3.4 Gas ConnectionsA. Connecting Gas Supply to UnitThe connection is the same for compressed air or high pressure gas cy

Seite 8

INSTALLATION 3-4 Manual 0-2967C. Installing Optional Single - Stage Air FilterAn optional filter kit is recommended for improved filtering with compre

Seite 9 - 1.08 Statement of Warranty

Manual 0-2967 3-5 INSTALLATIOND. Using High Pressure Gas CylindersWhen using high pressure gas cylinders as the gas supply:1. Refer to the manufacture

Seite 10

INSTALLATION 3-6 Manual 0-29673.5 Torch ConnectionsIf necessary, connect the torch to the Power Supply. Connect only the model SL60 Torch to this pow

Seite 11 - SECTION 2: SPECIFICATIONS

Manual 0-2967 4-1 OPERATIONSECTION 4:OPERATION4.01 Product FeaturesA. General FeaturesA-03287Handle and Leads WrapGas Pressure KnobTorch Leads Connect

Seite 13 - SECTION 3: INSTALLATION

OPERATION 4-2 Manual 0-2967B. Control PanelA-03283314562A30202628242271. ON / OFF SwitchControls input power to the power supply. Up is ON, down is O

Seite 14 - 120 V, 20A, 1Ø

Manual 0-2967 4-3 OPERATION4.02 Preparations For OperatingAt the start of each operating session:WARNINGDisconnect primary power at the source before

Seite 15 - 3.4 Gas Connections

OPERATION 4-4 Manual 0-2967F. Power OnPlace the Power Supply ON / OFF switch to the ON (up) position. AC indicator turns on. Gas indicator turns

Seite 16

Manual 0-2967 4-5 OPERATIONH. Select Current Output LevelPlace RUN / SET switch to RUN (up) position. Gas flow will stop. Set the desired current ou

Seite 17

OPERATION 4-6 Manual 0-2967K. Typical Cutting SpeedsCutting speeds vary according to torch output, the type of material being cut, and operator skill.

Seite 18 - 3.5 Torch Connections

Manual 0-2967 4-7 OPERATION4.03 Sequence of OperationThe following is a typical sequence of operation for this power supply. Refer to Appendix 1 for

Seite 19 - OPERATION

OPERATION 4-8 Manual 0-2967

Seite 20 - B. Control Panel

Manual 0-2967 5-1 SERVICESECTION 5:SERVICE5.01 General MaintenanceA. Each UseCheck torch consumables for wear, replace if necessary. WARNINGShut off

Seite 21 - E. Connect Work Cable

SERVICE 5-2 Manual 0-29674. Pull the upper end of the drain tube off the fitting on the filter bowl.5. Unscrew the bowl. The filter element will be

Seite 22 - G. Set Operating Pressure

Manual 0-2967 5-3 SERVICEB. Check Optional Single - Stage Filter Element, replace if necessary.1. Shut off input power.2. Shut off air supply, bleed

Seite 23 - J. Cutting Technique

WARNINGSRead and understand this entire Manual and your employer’s safety practices before installing, oper-ating, or servicing the equipment.While th

Seite 24 - M. Shutdown

SERVICE 5-4 Manual 0-29675.02 Common Faults1. Insufficient Penetrationa. Cutting speed too fastb. Torch tilted too muchc. Metal too thickd. Worn torc

Seite 25 - 4.03 Sequence of Operation

Manual 0-2967 5-5 SERVICE5.03 Basic Troubleshooting GuideWARNINGThere are extremely dangerous voltage and power levels present inside this unit. Do n

Seite 26 - OPERATION 4-8 Manual 0-2967

SERVICE 5-6 Manual 0-2967B. AC indicator flashing; Torch cannot be activated1. System is in protective interlock mode. (User held torch trigger

Seite 27 - Cover Removal

Manual 0-2967 5-7 SERVICEF. AC indicator ON; TEMP indicator ON1. Air flow blockeda. Check for blocked air flow around the unit and correct con

Seite 28

SERVICE 5-8 Manual 0-2967H. No cutting output; Torch activated; AC indicator ON; Gas flows; Fan operates1. Work cable not connected to work piece

Seite 29

Manual 0-2967 5-9 SERVICEM. Arc shuts off during operation; arc will not restart when torch switch is activated.1. Power Supply is overheated (TEMP

Seite 30 - 5.02 Common Faults

SERVICE 5-10 Manual 0-2967

Seite 31 - C. Common Symptoms

Manual 0-2967 6-1 PARTS LISTSSECTION 6:PARTS LISTS6.01 IntroductionA. Parts List BreakdownThe parts list provides a breakdown of all replaceable compo

Seite 32

PARTS LISTS 6-2 Manual 0-29676.05 Options and AccessoriesQty Description Catalog #1 Multi-Purpose Cart (Not Shown) 1445-09131 Single - Stage Filter K

Seite 33

Manual 0-2967 A-1 APPENDIXAPPENDIX 1: SEQUENCE OF OPERATION(BLOCK DIAGRAM)ACTIONON / OFF switchto OFFRESULTAll indicators off.Power supply fan shuts

Seite 34

TABLE OF CONTENTSSECTION 1:GENERAL INFORMATION ... 1-11.01

Seite 35

APPENDIX A-2 Manual 0-29671/3ff12West Lebanon, NH USA 03784Made in USAModel:U1111max 1effIIU23Ø3Ø1Ø1ØS/NU0=XStandard SymbolsØACDCPhaseNOTES:1. Symbol

Seite 36 - SERVICE 5-10 Manual 0-2967

Manual 0-2967 A-3 APPENDIXThis page left blank.

Seite 37 - B. Returns

APPENDIX A-4 Manual 0-2967APPENDIX 3: SYSTEM SCHEMATIC11223344ABCDEFAC3CURRENTCONTROL121MAIN PCB ASSEMBLY12J521P5GAS13DCFAN112P4TEMPJ422M1CURRENT ADJ

Seite 38 - Single - Stage Air Filter

Manual 0-2967 A-5 APPENDIX55667788991010ABCDEFSOL1J3122TORCHSWITCH2(13)P11J1T3(12)WORKP31OAGAS SOLENOIDCH11BR42COMP DESCRIPTIONSW1SW2M1 FAN, 4.5"

Seite 39 - (BLOCK DIAGRAM)

APPENDIX A-6 Manual 0-2967

Seite 40 - West Lebanon, NH USA 03784

May 14, 2002 1-1 GENERAL INFORMATIONSECTION 1:GENERAL INFORMATION1.01 Notes, Cautions and WarningsThroughout this manual, notes, cautions, and warning

Seite 41 - This page left blank

GENERAL INFORMATION 1-2 May 14, 2002• Wear dry gloves and clothing. Insulate yourselffrom the work piece or other parts of the weldingcircuit.• Repai

Seite 42 - APPENDIX 3: SYSTEM SCHEMATIC

May 14, 2002 1-3 GENERAL INFORMATION6. ANSI Standard Z49.2, FIRE PREVENTION IN THE USEOF CUTTING AND WELDING PROCESSES, obtain-able from American Nati

Seite 43 - Manual 0-2967 A-5 APPENDIX

GENERAL INFORMATION 1-4 May 14, 20021.07 Declaration of ConformityManufacturer: Thermal Dynamics CorporationAddress: 82 Benning StreetWest Lebanon, Ne

Seite 44 - APPENDIX A-6 Manual 0-2967

May 14, 2002 1-5 GENERAL INFORMATION1.08 Statement of WarrantyLIMITED WARRANTY: Firepower® (hereinafter “Firepower”) warrants that its products will

Kommentare zu diesen Handbüchern